Engineers, technicians and other technical personnel working in fields such as design, manufacturing and maintenance may attend.
30 hours (10 hours theory; 20 hours practice)
General Admission: 8.000₺ / IZU Staff and Students: 5.000₺
IZU Halkalı Campus
will be updated as soon as possible
Our certificate programme aims to provide participants with the ability to select and configure S7-1200 PLC hardware units and to carry out Basic and Intermediate Level PLC programming using Siemens TIA Portal software.
BASIC LEVEL
- What is a PLC
- Review of general digital electronics concepts
- Number and coding systems
- Explanation of the Bit, Byte, Word and Doubleword concepts
- Siemens S7 PLCs
- Components of a PLC
- PLC input-output units (signal modules-cards) (S7-1200 PLC I/O modules and configuration)
- Differences between the S7-200 and S7-1200 PLCs
- Programming software (programming interface) – (Introduction to TIA Portal software)
- Address areas used in the PLC
- Number systems
- Linear program processing
- S7-1200 hardware structure and hardware configuration, Device Configuration menu
- Addressing of PLC modules
- Program coding formats - ladder diagram (Ladder Diagram - LAD), function block diagram (Function Block Diagram: FBD), working logic of LAD/FBD programming
- Creating a project for the S7-1200 with TIA Portal
- Uploading the project on the PLC into the TIA Portal project (upload)
- Creating OB and FC, Download operation, Taking a backup
- Taking an online back-up with TIA Portal
- Backing up the project on the PC and restoring it from the backup
- Licensing procedures for "SIMATIC" programs
- Screen layouts in TIA Portal
- Mantık Fonksiyonları
- (ASSIGNMENT FUNCTION: Assigning a normally open contact, Assigning a normally closed contact)
- ("NOT" FUNCTION, "AND" FUNCTION, "OR" FUNCTION, "EXCLUSIVE OR" FUNCTION, WRITING A PROGRAM USING A TRUTH TABLE)
- Programming Instructions, Bit Logic
- Internal memory areas
- Memory function, Mutual interlocking of memory elements
- USE OF THE S7-1200 SIMULATOR (S7-PLCSIM) (USE OF PHYSICAL INPUT-OUTPUT SIGNALS, USE OF THE SIMULATOR TABLE, USE OF THE DATA EXCHANGE TABLE (SEQUENCE), PLCSIM_V17 AND LATER)
- TIMER function (TIMER TYPES IN THE S7-1200, TIMER PARAMETERS, PULSE GENERATOR (Clock memory bits))
- Counter function
- Project monitoring and modification (MONITORING AND MODIFYING ONLINE, MONITORING AND MODIFYING VIA THE TAG TABLE, MONITORING AND MODIFYING WITH THE "WATCH TABLE", MONITORING AND MODIFYING WITH THE "FORCE TABLE", CROSS-REFERENCES LIST, ASSIGNMENT LIST, PROGRAM CALL STRUCTURE, COMPARING PLC PROJECTS (COMPARE), USE OF THE S7 MEMORY CARD, "FIRMWARE" UPGRADE VIA TIA PORTAL, PROTECTION/ENCRYPTION IN TIA PORTAL PROJECTS AND CPUs)
- Application solutions
INTERMEDIATE LEVEL
- Yapısal programlama
- USING SUBROUTINES, USING DATA BLOCKS,
- PARAMETERISATION OF SUBROUTINES: Parameterisation of functions (FC...), Parameterisation of function blocks (FB...), Using multi instance data blocks, Using parameter instance data blocks,
- ORGANISATION BLOCKS (OB...)
- Sayısal operasyonlar
- DATA TYPES,
- MEMORY STRUCTURES IN SIEMENS PLCs,
- "MOVE" FUNCTION,
- USE OF "EN" AND "ENO" IN NUMERICAL OPERATIONS,
- COMPARISON OPERATIONS: Standard comparators, "IN_RANGE" Function, "OUT_RANGE" Function, -JOKI- Function, -INOT OKI- Function,
- NUMERICAL (WORD) LOGIC OPERATIONS: Masking, Overwriting, Complementing (INV), Decoder (DECO), Encoder (ENCO), Binary select (SEL) function, Multiplex (MUX) function, Demultiplex (DEMUX) function transferring the input to the selected output
- JUMP OPERATIONS: Conditional or unconditional jump (JMP-JMPN), Using the return (RET) instruction, Creating a jump list (JMP_LIST), Jumping according to a comparison result (SWITCH)
- SHIFT AND ROTATE OPERATIONS,
- ARITHMETIC FUNCTIONS,
- MATHEMATICAL FUNCTIONS: Square (SQR), Square root (SQRT). Calculator (CALCULATE)
- INCREMENT, DECREMENT, NEGATE AND ABSOLUTE VALUE FUNCTIONS.
- USING MINIMUM/MAXIMUM SELECTION AND LIMIT FUNCTIONS.
- LOGARITHM AND EXPONENTIAL FUNCTIONS: Natural logarithm (LN), Natural exponential (EXP), Exponentiation (EXPT), Logarithm conversion,
- TRIGONOMETRIC FUNCTIONS,
- CONVERSION BETWEEN DATA TYPES,
- Converting "REAL" numbers to integers,
- SCALE and NORMALISE functions,
- Operator panel selection and points to consider when selecting a panel,
- Introduction to the PLC communication structure and its settings (Ethernet settings),
- Creating a library block,
- Analog değerlerin işlenmesi
- SIGNAL TYPES: binary signal, Digital Signal, Analogue Signal.
- THE PRINCIPLE OF ANALOGUE SIGNAL PROCESSING IN THE PLC
- ANALOGUE SIGNAL INPUT AND OUTPUT
- DIGITISATION OF ANALOGUE SIGNALS (RESOLUTION)
- CONFIGURATION OF ANALOGUE CHANNELS
- TEMPERATURE MEASUREMENT WITH S7-1200 PLCs
- Screen transitions, Template screen, on-screen control elements (Button, I/O Field, Symbol Library)
- Use of the diagnostics buffer
- Graphical monitoring of PLC tags (traces).
- What a tag is, its types and use (Internal Tag, External Tag)
- Application solutions
Asst. Prof. Mohammed Vadi
Asst. Prof. Mohammed S. s. Jouda
Participants who successfully complete the program earn a certificate approved by the Istanbul Sabahattin Zaim University Continuing Education Center.
An 80% attendance requirement must be met during the training.
- Photocopy of national ID card (front side)
- IZUSEM reserves the right to make any changes it deems necessary during the announcement and implementation stages of its programmes.
- As the quota for the programme in question is limited, no refund will be made to participants who have been granted final registration by IZUSEM and have paid the programme fee, regardless of whether they attend the programme, except for those who submit a written application to IZUSEM stating that they will be unable to attend at least 2 weeks before the programme's start date.
- Weekday and weekend training groups will be determined according to the number of participants during the final registration period.